DUTIES AND RESPONSIBILITIES
• Conduct upper-air test flights, write test plans, reports, and technical notes for US and
Caribbean Upper-Air networks.
• Evaluate aerological sounding balloons, radiosonde workstation software, automatic launchers,
and new technologies.
• Conduct data continuity studies and support System Tests and Operational Test and Evaluation.
• Maintain Upper Air systems located at SFSC; assist in instruction of Upper Air system
maintenance classes.
• Develop and maintain a quality assurance program for the facility test programs and laboratory
operations, including: handbook of procedures, audit plan, personnel certification program, and
workflow management plan.
• Ensure measurements are within NWS and WMO requirements for accuracy.
• Develop and maintain user guides for all laboratory resources and SFSC documents on theory of
operation for laboratory standards and sensor types.
• Maintain traceability and uncertainty records for laboratory and calibrated assets.
• Maintain and update a database of status, location, and calibration cycle performance of all
primary calibration and testing standards and laboratory equipment.
• Coordinate calibration cycles and track all calibrated units, including property control,
calibration times, and location.
• Support NOAA/NWS WMO and other international initiatives as requested; support
SFSC/NESDIS/Howard University GRUAN operations and other initiatives.
• Assist the Government in web application development and maintenance (SFSC public and
private websites).
• Upgrade software data analysis tools and procedures to automate data collection and analysis;
conduct data analysis and Quality Control.
• Develop multiple databases and software interfaces to support data storage for test programs;
develop/finish relational database for sensor and related data.
• Operate laboratory assets in support of test programs; ensure at least two staff members are
proficient in all laboratories at all times.
• Perform yearly documentation review and updates to operational procedures.
• Gather quotes and generate requirements and justifications for acquisitions supporting the
PWS.
• Serve as document control manager for test and laboratory-related documents.
• Perform or assist in performing preventative maintenance and repairs of environmental
chambers and other test resources.
• Set up, install, test, and operate equipment used in SFSC laboratories and around the facility;
perform calibration of equipment.
• Analyze measurement data, develop and follow calibration procedures, generate calibration
certificates, perform uncertainty calculations, and troubleshoot processes and equipment.
• Seek out solutions and resolve technical issues independently; produce high-quality technical
writing.
QUALIFICATIONS
Education
B.S. degree in Physical Science (or equivalent major); M.S. degree desired.
Experience
Practical experience with weather data collection systems or weather-based systems is required.
Proficiency in Microsoft Office Suite. 6 or more years of experience in the test, calibration, and
evaluation of meteorological observing equipment. Must obtain operational, programming, and
maintenance certifications on laboratory equipment if working in laboratories.
Knowledge, Skills, and Abilities (KSAs)
• Ability to analyze and interpret meteorological data.
• Understanding of existing meteorological theory and the development or improvement of
meteorological methods, techniques, and instruments.
• Working knowledge of measuring meteorological phenomena with scientific equipment and
instrumentation.
• Ability to set up, install, test, and operate equipment used in SFSC laboratories.
• Ability to analyze measurement data, develop and follow calibration procedures, generate
calibration certificates, perform uncertainty calculations, and troubleshoot processes and
equipment.
• Ability to lead a team and delegate accordingly to meet mission objectives.
• Proficiency in technical writing.
• Individual capable of seeking out solutions and resolving technical issues independently.
Required Certifications
Must obtain a Certified Calibration Technician (CCT) Certification within 180 days of onboarding. Must
obtain a Pressure Standards Laboratory Certification within 90 days of onboarding (if applicable). Must
obtain NWS Surface or Upper Air Observing System Certification within 20 days of onboarding (if
applicable).
Additional Requirements
Must have availability to shift working hours for early morning, evening, or overnight testing and
calibration requirements when requested.
*Salary is negotiable based on experience*