Bachelor's degree in a related technical field or equivalent experience.
5+ years in IT infrastructure construction monitoring or telecom project inspection.
5+ years managing technical fit-outs with multi-disciplinary coordination.
5+ years reading and interpreting blueprints and architectural drawings.
5+ years applying BICSI standards and National Electrical Code (NEC).
5+ years using construction management software like Procore or Autodesk Build.
Responsibilities
Conduct daily on-site inspections to ensure compliance with design drawings.
Inspect structural elements like fiber conduits and cable trays.
Monitor infrastructure deployments for compliance with HVAC and power systems.
Audit physical placement of IT hardware such as switches and servers.
Verify structured cabling installations for quality and compliance.
Perform QA/QC audits on asset tags and cable labels.
Identify design gaps and contractor deviations during inspections.
Lead problem-solving sessions with contractors and engineers.
Issue and track Non-Conformance Reports (NCRs) and participate in RFIs.
Monitor construction progress against the project schedule.
Author daily and weekly progress reports with photographic evidence.
Maintain the project punch list from rough-in to final handover.
Benefits
On-site work at active construction sites.
Use of required personal protective equipment (PPE).
Opportunity to work on diverse IT infrastructure projects.
Full Job Description
IT Construction Monitoring and Commissioning Inspector
Job Overview
The IT Construction Monitoring and Commissioning Inspector verifies that IT infrastructure and technical fit-out elements are built, installed, and checked out in accordance with engineering design drawings, project specifications, and quality standards. This role bridges physical construction and IT hardware deployment by conducting daily site inspections, identifying technical deviations early, and resolving installation issues with general contractors and design engineers. The position requires critical thinking, the capacity to anticipate operational issues and propose viable engineering alternatives, and clear, diplomatic communication when negotiating fixes between field contractors and design engineers.
Key Responsibilities
Conduct daily on-site inspections to verify that construction matches IT, telecommunications, electrical, and mechanical design drawings.
Inspect structural and pathway elements, including fiber conduits, stub-ups, underground piping, cable trays, and equipment racks and cabinets.
Monitor supporting infrastructure deployments for compliance, including data center and Intermediate Distribution Frame (IDF) room Heating, Ventilation, and Air Conditioning (HVAC), cooling distribution, and dedicated IT power systems (Uninterruptible Power Supply (UPS), Power Distribution Unit (PDU), and grounding).
Audit the physical placement and mounting of IT hardware, including switches, routers, servers, patch panels, and wireless access points (WAPs).
Verify copper and fiber structured cabling installations for proper bend radius, support, slack loops, and termination quality.
Perform Quality Assurance/Quality Control (QA/QC) audits on asset tags, cable labels, and port mapping against the approved labeling schema and matrix.
Identify field conflicts, design gaps, and contractor deviations from design intent.
Lead collaborative problem-solving sessions with general construction contractors and Mechanical, Electrical, and Plumbing (MEP) and IT engineering designers to resolve field issues.
Issue and track Non-Conformance Reports (NCRs) and participate in the Request for Information (RFI) process.
Monitor field construction progress against the master project schedule, identifying potential bottlenecks and milestone risks.
Author daily and weekly progress reports that include photographic evidence, deviation logs, and remediation proposals.
Maintain the project punch list from initial rough-in through final IT checkout and owner handover.
This role requires on-site work at active construction sites and the use of required personal protective equipment (PPE).
Basic Qualifications
Bachelor's degree in a related technical field, or equivalent experience.
5+ years of experience in IT infrastructure construction monitoring, telecom project inspection, data center fit-outs, or Registered Communications Distribution Designer (RCDD)-level field representation.
5+ years of experience managing technical fit-outs involving multi-disciplinary coordination (Electrical, HVAC, Low Voltage, Network Engineering).
5+ years of experience reading and interpreting blueprints, architectural drawings, MEP schedules, single-line diagrams, and IT schematic layouts.
5+ years of experience applying Building Industry Consulting Service International (BICSI) standards, National Electrical Code (NEC), and structured cabling practices.
5+ years of experience using construction management software (e.g., Procore, Autodesk Build, PlanGrid) and scheduling tools.
Preferred Qualifications
Certifications such as BICSI RCDD or BICSI Technician.
Certifications such as Certified Technical Inspector (CTI) or relevant Amazon Web Services (AWS) or data center infrastructure credentials.
Certifications such as Occupational Safety and Health Administration (OSHA) 10-Hour or 30-Hour Construction Safety.