4+ years in thermal design, with 3+ years on e-houses or modular data centers.
Experience in calculating heat loads and HVAC equipment selection for electrical equipment spaces.
Knowledge of ASHRAE fundamentals, IMC/IECC, and NFPA standards relevant to battery rooms.
Hands-on experience with CFD tools like Ansys Fluent or SolidWorks Flow Simulation.
Proficient in 3D CAD software (SolidWorks or Inventor).
Strong communication skills for conveying design trade-offs.
Responsibilities
Own thermal design for e-houses and e-pods, ensuring compliance with temperature limits.
Calculate heat loads and select appropriate cooling and heating equipment.
Specify control sequences and coordinate with controls engineers.
Conduct thermal analysis and run CFD airflow simulations.
Design ventilation systems for battery rooms, ensuring safety and compliance.
Specify insulation and environmental controls to prevent condensation.
Write and execute HVAC test plans, supporting site commissioning efforts.
Benefits
Competitive salary with bonus potential.
Paid time off and 401K matching.
Comprehensive medical, dental, and vision benefits.
Opportunities for advancement in a high-growth organization.
Diverse and collaborative work environment.
Full Job Description
Hybrid: Travel: 30%
What We Offer:
Competitive Salary + Bonus Potential!
Paid Time Off, 401K Matching, Medical, Dental, and Vision Benefits!
High-growth organization with advancement opportunities!
Diverse, Collaborative, & Fun Work Environment!
About the Role:
This engineer owns the thermal design of Maverick's e-houses and e-pods. They make sure the power distribution gear inside every configuration stays within its rated ambient and listed temperature-rise limits, from design through FAT. They set the thermal design rules the modular platform uses, so later configurations are sized from validated methods instead of being redesigned each time.
Key Responsibilities:
Thermal design and equipment selection
Calculate heat loads for e-houses and e-pods, covering gear losses (switchgear, switchboards, PDUs, RPPs, ATS/STS, transformers, UPS), solar gain, envelope gain, and internal loads, across the full range of configurations.
Size and select cooling and heating equipment: wall-mount and packaged DX, split systems, chilled-water interfaces, and economizers. Define N+1 / 2N redundancy schemes that hold up under single-unit failure.
Specify controls sequences: lead/lag rotation, staging, alarm points, and the interface to EPMS/BMS (Modbus/BACnet), coordinated with the controls engineer.
Size HVAC electrical loads and give electrical design the data it needs for house power and emergency loads.
Thermal analysis and CFD
Set design ambient limits for the gear inside each enclosure and verify that the gear stays within its UL 1558 / UL 891 / UL 1008 temperature-rise and ambient ratings at worst-case load and site conditions.
Run CFD and first-principles airflow analysis: supply and return placement, hot spots, recirculation, and the effect of gear lineup orientation and arc-resistant plenum or vent paths.
Build reusable thermal sizing tools and rules (for example, heat load per section, BTU/hr per kVA by gear type) that cover the whole modular configuration space.
Battery room and energy storage ventilation
Design ventilation for VRLA and Li-ion battery rooms: hydrogen dilution, off-gas exhaust, and keeping battery temperature within manufacturer limits.
Coordinate with fire protection and listing on NFPA 855, UL 9540A test results, IFC/IMC requirements, and explosion control (deflagration venting or exhaust per NFPA 68/69).
Envelope, condensation, and environmental control
Specify insulation R-values, vapor barriers, and thermal breaks to prevent condensation and keep humidity under control across climate zones.
Define pressurization, filtration (MERV rating, corrosive and dusty environments), space heaters, and design for the cold-start and low-ambient cases.
Coordinate penetrations, gasketing, and NEMA 3R / IP sealing with mechanical and structural design.
Test, validation, and commissioning
Write HVAC and thermal test plans for first-article and FAT: temperature-rise validation inside the e-house, HVAC performance at load, redundancy failover, and water and enclosure-integrity tests.
Correlate test data back to the thermal models and close any gaps before the design is released as a standard.
Support site commissioning (Level 3-5 Cx) and field issues, and feed lessons learned back into the design standards.
Standards and cross-functional ownership
Author and maintain Maverick's HVAC/thermal design standards, calculation templates, and approved-vendor criteria for modular products.
Review drawings, BOMs, and vendor submittals. Drive DFM and cost-down while protecting thermal margin.
Manage HVAC suppliers on technical selection, lead time, and qualification.
Qualifications:
B.S. in Mechanical Engineering, or a closely related engineering degree.
Minimum of 4 years in thermal design, including at least 3 years on e-houses, e-pods, or modular data centers (modular data center experience counts as equivalent).
Experience calculating heat loads and HVAC equipment selection for spaces dominated by electrical equipment, and owned the results through test.
Working knowledge of ASHRAE fundamentals and climate data, IMC/IECC, NFPA 70 (NEC) working-space and ventilation requirements, and the requirements that apply to battery rooms (NFPA 855, NFPA 1 / IFC).
Hands-on with CFD (Ansys Fluent/Icepak, SolidWorks Flow Simulation, 6SigmaET, or equivalent) and with validating models against measured data.
Has written and run thermal or HVAC test procedures, including instrumenting thermocouples, data acquisition, and analyzing the results.
Proficient in 3D CAD (SolidWorks or Inventor) and comfortable reading electrical one-lines and gear elevations.
Communicates trade-offs clearly in writing to design, quality, test, and leadership.
Preferred Qualifications:
PE license (Mechanical), or EIT working toward a PE.
Experience with UL 1558, UL 891, or UL 1008 temperature-rise testing, or with UL 2755 (modular data center) evaluations.
Experience designing ventilation for Li-ion BESS or UPS battery rooms, including how UL 9540A results drive the design.
Experience with AI or high-density data center loads and liquid-cooling interfaces.
Design for outdoor and harsh sites: corrosive atmospheres, high altitude, extreme hot or cold, and seismic or wind-rated equipment mounting.
Built engineering standards or configuration rules for a product platform built to order.
ASHRAE certification (e.g., HBDP or BEMP) or Certified Data Centre Design Professional (CDCDP).
Physical Requirements:
Must be able to lift up to 40 pounds at a time.
Prolonged periods sitting at a desk and working on a computer.
Work Environment: May work in various settings at the Maverick Power facilities, in offices, in multiple shops, and in commercial buildings. Maintaining the same position or posture while performing tasks and sitting for prolonged periods. The above-noted job description is not intended to describe, in detail, the multitude of tasks that may be assigned but rather to give the applicant a general sense of the responsibilities and expectations of this position. As the nature of business demands change so, too, may the essential functions of the position.